Product Details

MD Series
MD-165

  • Model:MD
About this product
◆ Can dry rapidly, evenly at low temperature.
◆ The rate of broken rice would be low and the appearance rice will be beautiful, achieving high milling yield.
◆ Can use rice husk as biomass fuel to minimize drying costs.

    Product Introduction

    MD-165 Series
    • The low-temp., even and speedy drying minimizes broken grains and produces beautiful kernels. 
    • The entire dryer is designed to be strong and sturdy, making it suitable for heavy-duty.
    • With foolproof design, users can produce high-quality rice from the 1st, 100th to 1000th batch. 
     
    Grain consistent in quality will be available to customers.
    • Automatic moisture control prevents over-drying and weight loss.
    • By using self-milled free rice husk, users no longer need to spend on diesel, natural gas or electricty as dryers' heat sources.


    Multiple models with various fuel options availabl
    Heat SourceMD-165 Series
    Diesel
    Gas
    Biomass
    Steam
    Diesel & Husk Dual
    Gas & Husk Dual

    Application
    corn
    Paddy
    wheat


    Specifications
    ItemMD-165
    Heat SourceKerosene or Premium Diesel* 
    TypeGun type
    Combustion     
    Approx. liter/hr
    Maize             1 liter=690g27~54
    230,000~460,000 Kcal/hr
    Paddy            1 liter=560g11.3~27
    96,000~230,000 Kcal/hr
    Wheat            1 liter=680g11.3~27
    96,000~230,000 Kcal/hr
    Capacity     
    Approx. kg
    Maize             1 liter=690g7,000~16,500
    Paddy            1 liter=560g5,700~13,200
    Wheat            1 liter=680g6,900~16,200
    Dimension  L(A)×W(B)×H(C)mm5,341×3,626×10,272
    Net Weight  Approx. kg3,170
    Power Consumption  kWMaize 11.75      Paddy 11.25
    Function         Loading
    Approx. min
    Maize75
    Paddy, Wheat66
    Discharging
    Approx. min
    Maize70
    Paddy, Wheat65
    Drying Rate
    %/hr
    Maize1.8~2.6
    Paddy, Wheat0.7~1.2   Seed 0.2~1.0
    Electricity3P, 220V/380V/415V/440V, 50/60Hz
    Safety DevicesThermo-over relay, Air pressure switch, Full load buzzer, Timer,
    Control fuse, Burner flame sensor, Over-heat sensor
    *Use high-quality kerosene or premium diesel only.

     
    ItemMD-165G
    Low-tempHigh-temp
    Heat SourceLPGNGLPGNG
    Max. Combustion      Approx.Max.
    16.6kg/hr
    ≒233kW
    Max.
    18.2m3/hr
    ≒233kW
    Max.
    41.6kg/hr
    ≒581kW
    Max.
    45.5m3/hr
    ≒581kW
    Capacity     
    Approx. kg
    Maize             1 liter=690g-7,000~16,500
    Paddy            1 liter=560g5,700~13,200-
    Wheat            1 liter=680g6,900~16,200-
    FunctionLoading
    Approx. min
    Maize-75
    Paddy, Wheat66-
    Discharging
    Approx. min
    Maize-70
    Paddy, Wheat65-
    Drying Rate
    %/hr
    Maize-1.8~2.6
    Paddy, Wheat0.7~1.2-
    Dimension  L(A)×W(B)×H(C)mm5,341×3,930×10,272
    Net Weight  Approx. kg3,170
    Power Consumption  kW11.75
    TypeGun type
    Electricity 3P, 220V/380V/415V/440V, 50/60Hz
    Safety DevicesThermo-over relay, Air pressure switch, Full load buzzer, Timer,
    Control fuse, Burner flame sensor, Over-heat sensor

     
     
    ItemMD-165B
    Heat SourceSUNCUE Biomass Furnace BB-18, Rice Husk Furnace SB
    Capacity     
    Approx. kg
    Maize             1 liter=690g7,000~16,500
    Paddy            1 liter=560g5,700~13,200
    Wheat            1 liter=680g6,900~16,200
    Dimension  L(A)×W(B)×H(C)mm
    6,491×2,759×10,272
    Net Weight  Approx. kg3,520
    Required Thermal Energy
    Per unit approx.
    Maize 340,000 Kcal/hr
    Ambient Temp. +60°C
    Paddy, Wheat53,000~210,000 Kcal/hr
    Ambient Temp. +40°C
    Power Consumption  kW14.75
    Function
    Paddy
    Loading         
    Approx. min
    66
    Discharging 
    Approx. min
    65
    Drying Rate   
    %/hr
    0.7~1.2
    Electricity3P, 220V/380V/415V/440V, 50/60Hz
    Safety DevicesThermo-over relay, Air pressure switch,
    Full load buzzer, Timer, Control fuse
      

    ItemMD-165S-7MD-165S-12
    Heat SourceSteam
    Capacity     
    Approx. kg
    Maize             1 liter=690g7,000~16,500
    Paddy            1 liter=560g5,700~13,200
    Wheat            1 liter=680g6,900~16,200
    Dimension  L(A)×W(B)×H(C)mm4,710×2,810×10,2725,060×2,810×10,272
    Net Weight  Approx. kg3,9004,490
    Power Consumption  kW11
    Function
    Maize
    Loading          Approx. min75
    Discharging   Approx. min70
    Drying Rate    %/hr1.8~2.6
    Applicable RegionRegularRegular, Cold, Frigid
    Applicable GrainsPaddy, WheatPaddy, Wheat, Maize
    Temp. Increase Rang
    Approx. ambient temp.
    Maize +14~49°C
    Paddy +16~55°C
    Maize +25~72°C
    Paddy +27~80°C
    Boiler Capacity  Approx. ton/hr 1.01.2
    Boiler Pressure   Approx. kg/cm²7
    Electricity3P, 220V/380V/415V/440V, 50/60Hz
    Safety DevicesThermo-over relay, Air pressure switch,
    Full load buzzer, Timer, Control fuse


    Dimensions  
    Unit mm



    contact
    catalog
    maintenance
    Q&A

     

    Product Remark

    ● Above numbers and drying rate are derived from reducing moisture in paddy from 26% to 15%, wheat/corn from 30% to 12.5% ─ for reference only. Actual results vary among different ambient temperature, relative humidity, grain varieties, hot air temperature, moisture content before and after drying.
    ● Please apply low hot air temperature for drying paddy to prevent high breakage rate.
    ● Gas pipe lines have to be built by certified local professionals. NEVER do it by yourself.
    ● The specification and graph are for reference only. Actual specification of SUNCUE product shall be based on the Sales Confirmation which customers sign and delivered products.
    ● The specifications of burner shown above are Japanese standard (Thermal energy: NG 11,000 Kcal/m3; LPG 12,000 Kcal/kg). Please consult with SUNCUE for burner with CE standard.
    ● The density, composition and pressure of natural gas vary at different locations, thus thermal energy per m3 also varies. Ex: 8,900kcal/m3 in Taiwan, 11,000kcal/m3 in Japan, 8,400kcal/m3 in Sichuan province of China.
    ● Only use kerosene or premium diesel or diesel conformed to national standards. Please choose good quality diesel that can completely vaporize according to ambient temperature.
    ● Diesel/Rice Husk & Gas/Rice Husk Duel-type are made to order.
    ● Boiler is a dangerous device. It should be installed in a boiler house and operated by professionally-trained personnel with official license by laws. The operation must obey local government regulations.
    ● The required thermal energy is for reference only. Actual data will differ among grain variety, impurity rate, and drying condition.
    *Use high-quality kerosene or premium diesel only.

    Related Products